OEM Calibration Requirements Search
2016 Acura ILX
Click the links below for directions; definitions; articles; and additional RTS portal information such as OEM position statements and publications.
Camera in Deck Lid/Liftgate/Tailgate
OEM Name: Multi-View Rear Camera
Calibration/Initialization Requirement Events:
- No calibration/initialization requirements found
| Camera in Deck Lid/Liftgate/Tailgate | Yes | No | Not Identified |
| DTC Set | X | ||
| Scan Tool Required | X | ||
| Special Tools Required | X |
Camera Near Rearview Mirror
OEM Name: Multipurpose Camera
Calibration/Initialization Requirement Events:
- If DTC indicates
- If multipurpose camera unit is removed/installed or replaced
- If structural repairs are made
- If supplemental restraint system (SRS) is deployed
- If windshield is removed/installed or replaced
| Camera Near Rearview Mirror | Yes | No | Not Identified |
| DTC Set | X | ||
| Scan Tool Required | X | ||
| Special Tools Required | X |
Sensor(s) Behind Front Bumper Cover/Grille
OEM Name: Millimeter Wave Radar
Calibration/Initialization Requirement Events:
- If DTC indicates
- If front bumper cover is repaired within 300 mm of millimeter wave radar unit
- If millimeter wave radar unit is removed/installed or replaced
- If structural repairs are made
- If supplemental restraint system (SRS) is deployed
| Sensor(s) Behind Front Bumper Cover/Grille | Yes | No | Not Identified |
| DTC Set | X | ||
| Scan Tool Required | X | ||
| Special Tools Required | X |
Sensor(s) in Quarter Panel Behind Bumper Cover
OEM Name: BSI Radar Unit
Calibration/Initialization Requirement Events:
- No calibration/initialization requirements found
| Sensor(s) in Quarter Panel Behind Bumper Cover | Yes | No | Not Identified |
| DTC Set | X | ||
| Scan Tool Required | X | ||
| Special Tools Required | X |
Note:
Per the Acura Service Information manual, an operation check is required. (BSI Radar Unit Aiming Inspection)
| Additional Information | |